The Advanced Security Module/ASM (formerly referred to as an Exterior Door Kit or EDK) has two status LEDs.

Power LED:

Located on the side towards the Schlage RC’s pigtail.

A red LED indicates 12VDC power is being supplied to the ASM.

Communication Status LED:

Located on the side towards the lock wiring.

LED status meanings are described in the table below.

Schlage RC Locked Schlage RC Unlocked Lock State when Schlage RC is Unlocked Description or Item to Check
OFF GREEN Normal Operation
Flash Amber Flash Amber No Operation Yellow wire may be disconnected.
OFF Flash Amber No Operation White wire may be disconnected.
OFF Flash Amber No Operation Invalid encryption key received from Schlage Reader-Controller.
OFF OFF No Operation If power cycle of Schlage Reader-Controller allows for one or more lock operations, and then the lock stops operating, then the BackEMF diode may not be installed correctly.

Was this helpful?