Schlage RC

Product Information

Device Information and Settings

Device Information
Schlage RC
Overview
The Schlage RC wall mount is a next generation IP reader controller designed for scalable and flexible real-time access control in perimeter and high security applications
Submodels
RC11
RC15
RCK15
Applications
Perimeter Exits, Amenity Spaces, Common Areas, Enrollment Reader
Operating Mode
Online / Real time
Supports ResKey NFC Credentials
Yes
Support Zentra BLE Credentials
Yes
Number of Schedules Supported
16
Setting
Description
Contingencies
Options (Default)
Guarantees that at least one person is present when the door is open.
Works with AutoUnlock Schedules.
On: lock will remain locked until a user presents a credential to open the door. The lock will then stay unlocked until the end of the AutoUnlock period.
(Off)
: lock will unlock at the set unlock time.
Door Position Sensor (DPS: Door position sensor)
Senses whether the door is open or closed.
Physical DPS must be installed.
On: monitor the door status
(Off)
: do not monitor the door status
Set to match the normal state of the door.
Door Position Sensor
must be
On
.
Normally Open: Active Low
(Normally Closed)
: Active High
Set to match whether a physical latch is present or not.
Physical latch must be installed.
(On)
: Latch is installed Off: Latch is not installed
Number of seconds before the latch relocks after unlocking.
Latch
must be
On
.
Number of seconds, 1-30
(3)
Level of sensitivity that triggers a tamper event.
Low
(Medium)
High
Defines what the device should do when experiencing a power failure. Fail Safe should be used when free egress is necessary. Fail Secure should be used for high security applications.
Automatically set to Fail Secure if ASM is enabled, and cannot be changed.
(Fail Safe)
: device will move to unlocked state during power failure Fail Secure: device will move to locked state during power failure
Toggle whether proximity credentials will be read or not.
(On)
: Proximity credentials will be read Off: Proximity credentials will not be read
ASM (Advanced Security Module)
ASM must be paired and configured to test the latch.
Fail Mode will be set to Fail Secure.
On: ASM is associated
(Off)
: ASM is not associated
REX (Request for Exit)
Request to Exit output to strike/maglock.
REX
device must be physically present.
On
: REX output will be triggered
(Off)
: REX output will not be triggered
REX Input Type
Set to match the normal state of the door.
REX
must be
On
.
(Normally closed)
: door is normally closed Normally open: door is normally open
AUX (Auxiliary Input)
Toggle on to use AUX output. Used to trigger additional events when credential is read.
AUX
device must be physically present.
On
: AUX output will be triggered
(Off)
: AUX output will not be triggered
AUX Input Type
Set to match the normal state of the door.
AUX
Must be
On
.
(Normally closed)
: door is normally closed Normally open: door is normally open
AUX (Event)
Event that should occur when AUX is activated.
AUX
Must be
On
.
Admit: Device will move to unlocked state when AUX is activated.
(Report Only)
: Device will only report that AUX was activated.
Toggle whether the beeper should sound or not
(On)
: the lock beeper will sound. Off: the lock beeper will not sound.
Beeper Sounds
Indicate which event should cause the lock beeper to sound.
Beeper
must be
On
.
Event: beeper will sound for all events besides tamper Tamper Event: beeper will sound for tamper events
(Event, Tamper Event)
Toggle whether the device has a keypad or not.
Physical device must have a keypad (RCK15 Model).
(On)
: the physical device has a keypad Off: the physical device does not have a keypad
Keypad Backlight
Toggle whether the keypad backlight is on or off.
Keypad
must be
On
.
(On)
: backlight is on Off: backlight is off
Keypad Backlight Timeout
Indicate how long the keypad backlight should remain lit after user input.
Keypad
must be
On
. Keypad backlight must be
On
.
Number of seconds, 1-15
(3)
Toggle whether the door should lock when it is closed or not.
Door Position Sensor
must be
On
.
(On)
: lock will automatically move to locked state when closed Off: lock will not automatically move to locked state when closed
Door Prop Enabled
Toggle whether a door prop event should be generated when the door is propped open.
Door Position Sensor
must be
On
.
Works with
Door Prop Delay
.
On
: a door prop event will be generated when the door prop delay time is met
(Off)
: no door prop event will be generated
Door Prop Delay
The amount of time before a door prop event is generated.
Door Position Sensor
must be
On
.
Door Prop Enabled
must be
On
.
Number of seconds, 1-255
(20)