Schlage RC
Product Information
Device Information and Settings
Device Information | Schlage RC |
|---|---|
Overview | The Schlage RC wall mount is a next generation IP reader controller designed for scalable and flexible real-time access control in perimeter and high security applications |
Submodels | RC11 RC15 RCK15 |
Applications | Perimeter Exits, Amenity Spaces, Common Areas, Enrollment Reader |
Operating Mode | Online / Real time |
Supports ResKey NFC Credentials | Yes |
Support Zentra BLE Credentials | Yes |
Number of Schedules Supported | 16 |
Setting | Description | Contingencies | Options (Default) |
|---|---|---|---|
Guarantees that at least one person is present when the door is open. | Works with AutoUnlock Schedules. | On: lock will remain locked until a user presents a credential to open the door. The lock will then stay unlocked until the end of the AutoUnlock period. (Off) : lock will unlock at the set unlock time. | |
Door Position Sensor (DPS: Door position sensor) | Senses whether the door is open or closed. | Physical DPS must be installed. | On: monitor the door status (Off) : do not monitor the door status |
Door Position Sensor Input Type | Set to match the normal state of the door. | Door Position Sensor must be On . | Normally Open: Active Low (Normally Closed) : Active High |
Set to match whether a physical latch is present or not. | Physical latch must be installed. | (On) : Latch is installed Off: Latch is not installed | |
Number of seconds before the latch relocks after unlocking. | Latch must be On . | Number of seconds, 1-30 (3) | |
Defines what the device should do when experiencing a power failure. Fail Safe should be used when free egress is necessary. Fail Secure should be used for high security applications. | Automatically set to Fail Secure if ASM is enabled, and cannot be changed. | (Fail Safe) : device will move to unlocked state during power failure Fail Secure: device will move to locked state during power failure | |
Toggle whether proximity credentials will be read or not. | (On) : Proximity credentials will be read Off: Proximity credentials will not be read | ||
ASM (Advanced Security Module) | ASM must be paired and configured to test the latch. | Fail Mode will be set to Fail Secure. | On: ASM is associated (Off) : ASM is not associated |
REX (Request for Exit) | Request to Exit output to strike/maglock. | REX device must be physically present. | On : REX output will be triggered (Off) : REX output will not be triggered |
REX Input Type | Set to match the normal state of the door. | REX must be On . | (Normally closed) : door is normally closed Normally open: door is normally open |
AUX (Auxiliary Input) | Toggle on to use AUX output. Used to trigger additional events when credential is read. | AUX device must be physically present. | On : AUX output will be triggered (Off) : AUX output will not be triggered |
AUX Input Type | Set to match the normal state of the door. | AUX Must be On . | (Normally closed) : door is normally closed Normally open: door is normally open |
AUX (Event) | Event that should occur when AUX is activated. | AUX Must be On . | Admit: Device will move to unlocked state when AUX is activated. (Report Only) : Device will only report that AUX was activated. |
Toggle whether the beeper should sound or not | (On) : the lock beeper will sound. Off: the lock beeper will not sound. | ||
Beeper Sounds | Indicate which event should cause the lock beeper to sound. | Beeper must be On . | Event: beeper will sound for all events besides tamper Tamper Event: beeper will sound for tamper events (Event, Tamper Event) |
Toggle whether the device has a keypad or not. | Physical device must have a keypad (RCK15 Model). | (On) : the physical device has a keypad Off: the physical device does not have a keypad | |
Keypad Backlight | Toggle whether the keypad backlight is on or off. | Keypad must be On . | (On) : backlight is on Off: backlight is off |
Keypad Backlight Timeout | Indicate how long the keypad backlight should remain lit after user input. | Keypad must be On . Keypad backlight must be On . | Number of seconds, 1-15 (3) |
Toggle whether the door should lock when it is closed or not. | Door Position Sensor must be On . | (On) : lock will automatically move to locked state when closed Off: lock will not automatically move to locked state when closed | |
Door Prop Enabled | Toggle whether a door prop event should be generated when the door is propped open. | Door Position Sensor must be On .Works with Door Prop Delay . | On : a door prop event will be generated when the door prop delay time is met (Off) : no door prop event will be generated |
Door Prop Delay | The amount of time before a door prop event is generated. | Door Position Sensor must be On .Door Prop Enabled must be On . | Number of seconds, 1-255 (20) |