Alert Type | Description | Requirements | Actions | Devices | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
AUX Alarm | Auxiliary Alarm | AUX Device must be installed and configured in Device settings. | Dependent on configuration. | X | X | ||||||
Brute force Mitigation | Brute force attack was detected and mitigations initiated. | Increases the time between when card reads accepted once initiated. Events related to a previously detected brute force attack are stopped and device deactivated. | X | ||||||||
Credential Expired | A credential which has exceeded its time limit has been presented to a reader. | Access not granted | X | X | X | X | |||||
Credential Over Limit | A credential which has exceeded its count limit has been presented to a reader. | Count limit is configured in Special Properties. | Access not granted | X | |||||||
Credential Rejected | A credential with insufficient access has been presented to a reader. | Access is configured in Assign property access.
Alerts are not generated for Schlage RC when it is set to Enrollment Reader. | Access not granted | X | X | X | X | ||||
Critical Battery | Batteries are very low. | Batteries must be replaced immediately. See battery replacement information in the Product Information for the specific Device Type. | X | X | X | X | X | ||||
Alert from a Custom Rule | Custom Rules are set in Custom rules. | Dependent on configuration. | X | X | X | X | X | X | X | X | |
Door Position Sensor Tamper | DPS Tamper alert. | DPS must be physically installed and Door Sense enabled in the Device settings. | DPS should be physically inspected. | X | X | X | X | ||||
A Door was left open for an extended period of time. | DPS must be physically installed and Door Sense enabled in the Device settings. | Device and opening should be physically inspected. | X | X | X | ||||||
Interior Push Button Activated | IPB pressed. | IPB available on specific Device. | Dependent on configuration. | X | X | X | |||||
Low Battery | Batteries are low. | Batteries must be replaced soon. See battery replacement information in the Product Information for the specific Device Type. | X | X | X | X | X | ||||
Reader Tamper Alert | Reader was tampered with. | Reader should be physically inspected and reset. | X | X | X | ||||||
REX Alarm | Request for Exit was triggered. | REX switch must be physically installed and REX enabled in the Device settings. | X | X | |||||||
A Door was opened without valid access. Usually forced entry. | Device should be physically inspected and reset. | X | X | X | X | X | X | X | |||
* Available soon.