Alert Types

Alert Type
Description
Requirements
Actions
Devices
AUX Alarm
Auxiliary Alarm
AUX Device must be installed and configured in Device settings.
Dependent on configuration.
X
X
Brute force Mitigation
Brute force attack was detected and mitigations initiated.
Increases the time between when card reads accepted once initiated. Events related to a previously detected brute force attack are stopped and device deactivated.
X
Credential Expired
A credential which has exceeded its time limit has been presented to a reader.
Access not granted
X
X
X
X
Credential Over Limit
A credential which has exceeded its count limit has been presented to a reader.
Count limit is configured in Special Properties.
Access not granted
X
Credential Rejected
A credential with insufficient access has been presented to a reader.
Access is configured in Assign property access.
Alerts are not generated for Schlage RC when it is set to Enrollment Reader.
Access not granted
X
X
X
X
Critical Battery
Batteries are very low.
Batteries must be replaced immediately. See battery replacement information in the Product Information for the specific Device Type.
X
X
X
X
X
Alert from a Custom Rule
Custom Rules are set in Custom rules.
Dependent on configuration.
X
X
X
X
X
X
X
X
DPS Tamper alert.
DPS must be physically installed and Door Sense enabled in the Device settings.
DPS should be physically inspected.
X
X
X
X
A Door was left open for an extended period of time.
DPS must be physically installed and Door Sense enabled in the Device settings.
Device and opening should be physically inspected.
X
X
X
Interior Push Button Activated
IPB pressed.
IPB available on specific Device.
Dependent on configuration.
X
X
X
Low Battery
Batteries are low.
Batteries must be replaced soon. See battery replacement information in the Product Information for the specific Device Type.
X
X
X
X
X
Reader Tamper Alert
Reader was tampered with.
Reader should be physically inspected and reset.
X
X
X
REX Alarm
Request for Exit was triggered.
REX switch must be physically installed and REX enabled in the Device settings.
X
X
Device was tampered with.
Device should be physically inspected and reset.
X
X
X
X
X
A Door was opened without valid access. Usually forced entry.
Device should be physically inspected and reset.
X
X
X
X
X
X
X
* Available soon.