Product Information

XE360 Wireless Tubular Lock
XE360 Wireless Mortise Lock
XE360 Wireless Exit Trim

Device Information and Settings

Device Information XE360
Overview The innovative FleX module allows the XE360 Series to be easily upgraded in the field to allow migration from an offline to networked solution and to adapt to emerging trends in security and connectivity down the road.
Submodels XE360i – LED indicator XE360b – Internal push button XE360d – Deadbolt
Applications Resident Units, Perimeter Exits, Amenity Spaces, Common Areas
Operating Mode Offline
Supports ResKey NFC Credentials Yes
Support Zentra BLE Credentials Yes
Number of Users Supported 2,000
Number of Audits Supported 2,000
Setting Description Contingencies Options (Default)
First Person In Guarantees that at least one person is present when the door is open. Works with AutoUnlock Schedules. On: lock will remain locked until a user presents a credential to open the door. The lock will then stay unlocked until the end of the AutoUnlock period.
(Off): lock will unlock at the set unlock time.
Door Sense (DPS: Door position sensor) Senses whether the door is open or closed. Physical DPS must be installed. On: monitor the door status
(Off): do not monitor the door status
Door Prop Delay The amount of time before a door prop event is generated. Door Sense must be On.
Door Prop Enabled must be On.
1-255 seconds
(20)
Latch Interval (Relock delay) Number of seconds before the latch relocks after unlocking. Latch must be On. 1-30 seconds
(3)
Fail Modes Defines what the device should do when entering Critical Battery Mode. Fail Safe should be used when free egress is necessary. Fail Secure should be used for high security applications. Automatically set to Fail Secure if ASM is enabled, and cannot be changed. (Fail Safe): device will move to unlocked state during power failure
Fail Secure: device will move to locked state during power failure
Beeper Toggle whether the beeper should sound or not (On): the lock beeper will sound.
Off: the lock beeper will not sound.
Beeper Sounds Indicate which event should cause the lock beeper to sound. Beeper must be On. (Event): beeper will sound for each event
Tamper Event: beeper will sound for tamper events
Lock Function Apartment: Door doesn’t relock automatically to prevent the user from being locked out of their residence. The interior pushbutton or deadbolt will allow the resident to lock the door from the inside.
Office: Uses the interior pushbutton or deadbolt to allow the users to lock the door from the inside. Can be overridden by a valid credential.
Privacy: Uses the interior pushbutton or deadbolt to allow the user to lock the door from the inside. While in Privacy Mode, valid credentials are denied access
Storeroom: The lock is secure until a valid credential is presented. The inside lever will always open the door.
XE360I will always be Storeroom and cannot be changed. XE360I: (Storeroom)
XE360B & XE360D: Apartment, Office, Privacy, (Storeroom)
Blink Interior LED Toggle whether the interior LED should blink or not DPS must be On. On: the LED on the inside of the device to blink while the door is locked and closed
(Off): the LED will not blink
Blink Interval Indicates how quickly the interior LED blinks. DPS must be On.
Blink Interior LED must be On.
(Normal)
Rapid
Mechanical Override Detection Toggle whether a mechanical override event should be generated when the mechanical key is used. (On): mechanical override event will be generated when key is used.
Off: no event will be generated
Last Sync time The date/time the device was updated via the mobile app sync n/a